The disposable obstetric pack consists of surgical items (surgical gowns, gloves), obstetric items (leggings, pad sheets, fenestrated towels, blood towels, perineal pads, baby cloth), and omphalotomy pack (umbilical knots, cotton swabs, umbilical cord protective bands, surgical stitches, gauze pieces).
product information
ApplicationFor used by medical institutions during the delivery operation.
FeaturesThe material used to make the obstetric surgical packs is nonwoven fabrics, paper, plastic film and fat-free gauze.It has been widely used in clinical and daily life.The product has been sterilized by ethylene oxide,for single use, convenient and practical.
UsageFollow the normal operation of delivery operation.
StorageShould be stored in the relative humidity not more than 80%, non-corrosive gas and well-ventilated indoor, avoid high temperature.
Principle and ApplicationThe obstetric pack contains three units, among which the surgical items are for the doctor to wear, the obstetric items for the protection of the patients, and the omphalic items for the protection of the newborn.The surgical pack provides the function of isolating, protecting and dressing to the surgeon and the patient.
Appearance
1.   The appearance of the surgical pack should be correct, the surface should be clean, odor-free, there should be no damage defects.
2.   The sewing or heat seal and fold of surgical pack should be uniform, straight and firm.
Material Requirements
1.non-woven: a) mass per unit area ratio:Surgical gowns should be used25g/m2 Baby cloth should be used30g/m2 the others should be used 15g/m2;b)disruptive force:lengthways disruptive force10N;crosswise disruptive force10N;c)Ventilation Property1000mm/s
 d)humidity resistanceThe front of surgical gowns dip not less than GB/ t4745-1997 level 3.
2.disposable rubber examination glovesa)sizeIt should meet the requirement of 6.1 in GB/T4745-1997:watertightness b)It should meet the requirement of 6.2 in GB10213-2006.
3.Absorbent gauze:a)Soluble substance in waterThe total amount of soluble matter in water should be no more than 0.5%  b)loss on drying
The quality loss shall not be greater than 8.0%;
4.Surgery suturesThe surface of the sutures should be smooth and  homogeneity , without stains or knots
5.Cotton swaba)Josephalbert force:The cotton should be able to withstand pulling and not falling off completely.b)Folding resistanceBamboo stems should be able to withstand 100g pressure for 1min without breaking.
skin irritation
The response should be minimal.
Health indicators
1The product should be sterile after an effective sterilization process.
2After sterilization for 14d, the ethylene oxide residue should be less than 10μg/g.

评论

此博客中的热门博文

Effect of Electron Beam I Irradiation on Breaking Strength of Medical Disposable Protective Clothing Material

  Abstract: Disinfection or sterilization is an important part of the production process of medical disposable protective clothing (referred to as medical protective clothing). Compared with ethylene oxide sterilization method, irradiation is faster and more efficient. Since medical protective clothing has strict requirements in terms of protection performance,the radiation effect of its materials has important research significance. The electron beam accelerator was used to treat three kinds of medical  protective clothing  materials polypropylene (PP), polyester fiber (PET) and Tyvek with different absorbed doses. Then the samples were subjected to aging tests for different time. The main performance indicators related to radiation effect in GB 19082-2009 were tested. Test results show that the performances of the three kinds of medical  protective gown  such as resistance to water penetration, resistance to synthetic blood penetration, and filtration efficien...

Design And Nursing Application of Disposable Medical Surgery Sterile Operation Package

  Abstract: Preoperative time-out verification is an important procedure for surgical safety verification. In order to improve the implementation rate and satisfaction of medical and nursing Time-out surgical safety verification, this study designed a disposable medical surgical sterile surgical kit. The time-out indicator label is added to the incision site of the  surgical gown , which meets the use requirements of the time-out confirmation in the operating room. Compared with the old  surgical package , surgeons and nurses have significantly improved the implementation rate and satisfaction of Time-out surgical safety verification (P<0.05). The implementation rate of Time-out surgery safety verification in the new surgical kit group was 100.0%, which was significantly higher than the 70.0% in the old surgical kit group (t=11.863, P=0.001<0.05); the satisfaction of the surgeons and nurses in the new  surgical kit  group They were 95.3±3.5 and 96.2±3.8, w...

Classification of Surgical Gowns

  Surgical gowns   are a type of   isolation clothing  worn for protection from pathogens during surgery. They provide an extra layer of cleanliness and hygiene to the surgical team, which is especially important in the hospital setting where more than one patient may be undergoing surgery at any given time. The first step to choosing a   surgical gown   for your practice is determining what fabric you prefer: cotton or synthetic? Cotton offers superior comfort and breathability but can wear out quicker than some synthetics; whereas synthetic fabrics offer more durability but a less natural feel. Synthetic fabrics also tend to cost less on average than cotton ones do – so it’s really up to you! These fabrics have large pores through which microorganisms can easily flow, resulting in poor barrier qualities. Closely woven textiles should be combined with polyester and long-staple cotton and treated with liquid-repellent fluorocarbons to improve the barrier qu...