跳至主要内容

International Standards For Protective Gown

 (1) Disposable non-woven (non-woven fabric) materials are basically used for medical protective gown  internationally. There are certain differences in the focus of protective gown indicators, product performance requirements, test methods, etc. in each country, due to different test methods The key project indicators cannot be simply compared based on data.


(2) In GB19082-2009 "Technical Requirements for Medical Disposable Protective Clothing", the filtration efficiency of key indicators is not mentioned in other national standards. However, some key indicators such as "microbial penetration, anti-pollutant penetration and other test items are not involved, and both the US and EU standards have impermeable requirements.


(3) In addition to the key index requirements, in terms of physical safety during use, NFPA 1999 also requires strengths such as tearing, seams, item breaks, punctures, etc. in addition to the breaking strength requirements for emergency medical protective clothing , And the overall thermal comfort of emergency medical protective clothing is also required. GB 19082 only considers the breaking strength of the key parts of protective clothing and surgical gowns during the test. There is no requirement for tearing or bursting, and there are certain risks in use.


(4) Regarding the requirements for taking comfort, the Chinese, American and European standards have different focuses. The Chinese standards have requirements for moisture permeability, while the American standards focus on the requirements for warmth performance.


(5) American protective gown standard ANSI/AAMI PB 70: 12 standard divides the isolation ability of protective clothing into 4 levels. Among them, the products with the highest protection level are required to pass the two key test standards of ASTM F1670 (synthetic fluid penetration) and ASTM F1671 (virus penetration). It must pass at least ASTM F1670 test to meet the minimum standard of China's national standard medical protective clothes.


(6) The European standard protective gown consists of two sub-standard systems, the EN14126 standard for infection prevention and the TYPE sub-standard for resistance to gas, liquid, and solid particle penetration. According to different protection objects, European standard protective clothing is divided into 6 types: TYPE 1 and TYPE 2 for gas-level protection, TYPE 3/4/6 for liquid protection, TYPE 5 for solid and aerosol particle protection and clothing Tear strength. European standard protective clothes anti-synthetic blood penetration test reference standard ISO 16603. The standard classifies the protective gown penetration resistance to synthetic fluids into 6 levels, with 6 being the highest. Both ISO 16603 Level 2 (CLASS 2) and the Chinese National Standard are 1.75kPa. European standard protective clothing must have EN14126, and at least reach TYPE4, in order to meet the national standard.


GN0J))D3S)[5C)T[%[1A}M5.png

评论

此博客中的热门博文

Effect of Electron Beam I Irradiation on Breaking Strength of Medical Disposable Protective Clothing Material

  Abstract: Disinfection or sterilization is an important part of the production process of medical disposable protective clothing (referred to as medical protective clothing). Compared with ethylene oxide sterilization method, irradiation is faster and more efficient. Since medical protective clothing has strict requirements in terms of protection performance,the radiation effect of its materials has important research significance. The electron beam accelerator was used to treat three kinds of medical  protective clothing  materials polypropylene (PP), polyester fiber (PET) and Tyvek with different absorbed doses. Then the samples were subjected to aging tests for different time. The main performance indicators related to radiation effect in GB 19082-2009 were tested. Test results show that the performances of the three kinds of medical  protective gown  such as resistance to water penetration, resistance to synthetic blood penetration, and filtration efficien...

Design And Nursing Application of Disposable Medical Surgery Sterile Operation Package

  Abstract: Preoperative time-out verification is an important procedure for surgical safety verification. In order to improve the implementation rate and satisfaction of medical and nursing Time-out surgical safety verification, this study designed a disposable medical surgical sterile surgical kit. The time-out indicator label is added to the incision site of the  surgical gown , which meets the use requirements of the time-out confirmation in the operating room. Compared with the old  surgical package , surgeons and nurses have significantly improved the implementation rate and satisfaction of Time-out surgical safety verification (P<0.05). The implementation rate of Time-out surgery safety verification in the new surgical kit group was 100.0%, which was significantly higher than the 70.0% in the old surgical kit group (t=11.863, P=0.001<0.05); the satisfaction of the surgeons and nurses in the new  surgical kit  group They were 95.3±3.5 and 96.2±3.8, w...

Classification of Surgical Gowns

  Surgical gowns   are a type of   isolation clothing  worn for protection from pathogens during surgery. They provide an extra layer of cleanliness and hygiene to the surgical team, which is especially important in the hospital setting where more than one patient may be undergoing surgery at any given time. The first step to choosing a   surgical gown   for your practice is determining what fabric you prefer: cotton or synthetic? Cotton offers superior comfort and breathability but can wear out quicker than some synthetics; whereas synthetic fabrics offer more durability but a less natural feel. Synthetic fabrics also tend to cost less on average than cotton ones do – so it’s really up to you! These fabrics have large pores through which microorganisms can easily flow, resulting in poor barrier qualities. Closely woven textiles should be combined with polyester and long-staple cotton and treated with liquid-repellent fluorocarbons to improve the barrier qu...