跳至主要内容

博文

目前显示的是 三月, 2021的博文

Design And Nursing Application of Disposable Medical Surgery Sterile Operation Package

  Abstract: Preoperative time-out verification is an important procedure for surgical safety verification. In order to improve the implementation rate and satisfaction of medical and nursing Time-out surgical safety verification, this study designed a disposable medical surgical sterile surgical kit. The time-out indicator label is added to the incision site of the  surgical gown , which meets the use requirements of the time-out confirmation in the operating room. Compared with the old  surgical package , surgeons and nurses have significantly improved the implementation rate and satisfaction of Time-out surgical safety verification (P<0.05). The implementation rate of Time-out surgery safety verification in the new surgical kit group was 100.0%, which was significantly higher than the 70.0% in the old surgical kit group (t=11.863, P=0.001<0.05); the satisfaction of the surgeons and nurses in the new  surgical kit  group They were 95.3±3.5 and 96.2±3.8, w...

Effect of Electron Beam I Irradiation on Breaking Strength of Medical Disposable Protective Clothing Material

  Abstract: Disinfection or sterilization is an important part of the production process of medical disposable protective clothing (referred to as medical protective clothing). Compared with ethylene oxide sterilization method, irradiation is faster and more efficient. Since medical protective clothing has strict requirements in terms of protection performance,the radiation effect of its materials has important research significance. The electron beam accelerator was used to treat three kinds of medical  protective clothing  materials polypropylene (PP), polyester fiber (PET) and Tyvek with different absorbed doses. Then the samples were subjected to aging tests for different time. The main performance indicators related to radiation effect in GB 19082-2009 were tested. Test results show that the performances of the three kinds of medical  protective gown  such as resistance to water penetration, resistance to synthetic blood penetration, and filtration efficien...

Fabrication And Application of Orthopedic Patient Gown

  When changing clothes for patients with fracture or dislocation of joint, although routine orthopedic care has been performed, the healthy limb shall be removed first before the affected limb is removed, and the affected limb shall be worn first before the healthy limb is worn, and two nurses shall be required to operate, one to lift the affected limb and the other to replace it, so as to alleviate the pain of the patient. In practice, patients are often reluctant to change clothes because of the pain caused by the replacement, or the affected limb is unable to wear clothes. Especially in patients with bilateral or multiple fractures. For this reason, Our company-MedPurest design and manufacture the orthopedic  patient gown , through clinical trials, the effect is satisfactory. 1. Clinical data Three different colors of cotton (small and large sizes for different colors) flat elastic bands, buttons. 2, the production method The length of the trousers is the same as...

Personal Protective Equipment For Baiosafety Laboratories(B)

  2. No sharp objects (knives, needles, broken glass, etc.) should be exposed in the laboratory. Scissors should be put back into the box immediately after use. Disposable needles should be put into the lunch box for autoclaving; breaking glassware must Collect all debris immediately; 3. Check whether the gloves are leaking before use 4. When there is skin damage on the hands or other exposed parts of the body, all work should be stopped, and the experimental work can be carried out after the wound has healed. 5. If the skin is cut during the poisoning experiment, the wound should be immediately immersed in the disinfectant and the blood should be squeezed out as much as possible 6. When encountering other accidents in the experiment (such as fire, etc.), the source of infection should be eliminated immediately while the accident is eliminated, so as to prevent being infected or infecting other people; 7. After the experiment is completed, the work surface must be disinfected and t...

Personal Protective Equipment For Biosafety Laboratories(A)

  Biosafety protection The first barrier: Biological safety equipment and personal protective equipment constitute the first barrier. The second barrier: laboratory facilities are also called the second barrier, which refers to the special design and construction requirements of the laboratory. The third barrier: The laboratory management system (software part) constitutes the third barrier of biosafety protection. Including standardized operating procedures and strict laboratory management. Primary barrier The primary protective barrier of the biosafety laboratory is: biosafety cabinet and personal protective equipment. a) The biological safety cabinet is divided into 3 levels, Ⅰ, Ⅱ, and Ⅲ. b) Personal protective equipment includes masks, masks, glasses, various protective clothing, caps, pants, shoes, boots, socks, gloves, etc. Secondary barrier The facility structure and ventilation design of the laboratory constitute a secondary protective barrier According to the safety requir...